SR4P3A1B24
Usedformonitoringemergencystopswitches,safetydoorswitches,anddualPNPoutputsafetylightcurtains.characteristic:1、Detectableshortcircuitfaultsininputcontacts;2、Canchoosebetweencontrolledmanualresetandaut...
Used for monitoring emergency stop switches, safety door switches, and dual PNP output safety light curtains.
characteristic:
1、Detectable short circuit faults in input contacts;
2、Can choose between controlled manual reset and automatic reset;
3、Circuit with self monitoring;
4、Real time monitoring of working status;
5、Multiple models available for selection。
PL e;Security category:Cat.4; SIL 3。
Technical Parameter:
model | SR4P3A1B24 |
RESET MODE | Manual or automatic |
Working power supply | DC/AC24V |
consumption | 3W |
Output contact | 3N/O,1N/C |
switching capacity | AC-15,5A/250V; DC-13,6A/24V |
Release buffer time | <15ms |
Diagnostic Coverage | >99% |
Mean time between dangerous failures | 111a |
Average hourly hazardous failure rate | 2.5×10-8 |
protection grade | IP50 |
operation temperature | -10 ~+55℃ |
storage temperature | -40 ~+85℃ |
Wire cross-sectional area | Max. 2.5mm2 |
Length | Longest Max. 100m |
size | 96(L)×22.5(W)×116(H)mm |
Compliant with standards | EN 60947-5-1, EN 61000-6-2, EN 61000-6-3, IEC/EN 60204-1, EN ISO 13849-1 |
Wiring diagram:
exit:

EMERGENCY STOP:

Connected to safety light curtain (PNP output):